What Are The Common RCD Issues You Should Be Aware Of?

  • by

Residual Current Devices (RCDs) are essential for safeguarding people and property from electrical faults. By constantly monitoring the flow of electricity in a circuit, an RCD can detect when electricity is leaking, such as when a person comes into contact with a live wire, and promptly shut off the power. This fast reaction helps prevent severe injury, electrical fires, and equipment damage.

Despite their importance, RCDs are not immune to problems. Various issues can compromise their effectiveness or cause them to function incorrectly. Here is a detailed explanation of the most common RCD issues, with practical advice.

Why not try here on our website for additional resources?

Nuisance Tripping

Nuisance tripping refers to situations where an RCD trips, cutting off power, without a serious electrical fault. While this behaviour shows that the RCD is sensitive and operational, it also causes inconvenience and frustration when it happens frequently.

Common Causes

  • Moisture exposure: Outdoor outlets or sockets near wet areas can allow moisture ingress, causing small leakages that trip the RCD.
  • Ageing appliances: Older or poorly maintained appliances may have insulation breakdowns or earth leakage faults.
  • Multiple small leakages: Devices with minor leakage currents can add up to exceed the RCD’s threshold.
  • Neutral-earth faults: Wiring errors where neutral and earth are connected can cause false tripping.

How To Fix It

  1. Unplug appliances one at a time and reset the RCD to identify which device may be at fault.
  2. Avoid overloading a single RCD-protected circuit with many devices.
  3. Ensure moisture-prone areas are adequately sealed and outlets are weatherproof.
  4. Engage an electrician to test the wiring and correct any neutral-earth faults.

Incompatibility With Modern Devices

Modern electrical devices generate small amounts of DC (direct current) leakage, especially switch-mode power supplies. Standard RCDs, especially Type AC models, are designed to detect only AC leakage. As a result, they may not recognise DC faults and fail to trip when they should.

Devices That Cause Issues

  • Laptops and desktop computers
  • EV charging stations
  • Solar panel inverters
  • Washing machines with inverter motors
  • LED lighting transformers

Why It Matters

An RCD that can’t detect the type of leakage it encounters may allow a fault to go uncorrected. This leaves people and property unprotected, defeating the purpose of having the safety device installed.

How To Fix It

  • Upgrade RCDs to Type A, which can detect both AC and pulsating DC faults.
  • In more complex or sensitive environments, consider Type B RCDs.
  • Use RCBOs for each circuit to isolate individual problems and improve reliability.

Poor Or Incorrect Installation

If an RCD is wired incorrectly, it may fail to provide the intended protection. Sometimes, the RCD may trip unnecessarily or not during a genuine fault.

Common Installation Mistakes

  • Miswiring of neutral and active conductors.
  • Shared neutrals across different circuits.
  • Installing the wrong type of RCD for the circuit load.
  • Poor terminations or loose connections.

Signs Of Trouble

  • The RCD trips even when nothing is plugged in.
  • Pressing the test button does not cause it to trip.
  • Lights flicker when other appliances are turned on.

How To Fix It

  • Only allow licensed electricians to install or modify RCDs.
  • Insist on receiving a compliance certificate after any electrical work.
  • Consider a full switchboard inspection if ongoing problems persist.

Ageing And Wear

Like any device, RCDs wear out over time. Electrical stress, environmental conditions, and frequent tripping contribute to their degradation.

Signs Of Ageing

  • RCD is physically damaged, discoloured, or warm to the touch.
  • It doesn’t trip when the test button is pressed.
  • Trips are made randomly without a clear cause, especially after many years in service.

Why It’s A Risk

An ageing RCD may become less sensitive, fail to trip in time, or not at all, leaving the circuit unprotected against fault currents.

What To Do

  • RCDs should be tested every three months using the built-in “T” button.
  • Replace RCDs at least every 10 years, or earlier if faults occur.
  • Arrange professional testing every two years, even if the device appears functional.

Environmental Factors

RCDs installed in locations exposed to moisture, dust, salt, or chemicals may develop faults due to corrosion or contamination.

Common Situations

  • RCDs in garages, basements, or outdoor switchboards.
  • Installations near the ocean, where salt air corrodes terminals.
  • Dust and insect ingress can cause malfunction or short circuits.

Prevention Measures

  1. Use IP-rated weatherproof enclosures for RCDs exposed to the elements.
  2. Inspect external switchboards for signs of water or dust ingress.
  3. Use filters and seals to protect terminals in exposed areas.

Grouping Too Many Circuits On One RCD

One RCD protecting multiple circuits is a standard cost-saving measure in older installations. While this offers basic protection, it increases the likelihood of false tripping and reduces fault isolation.

Issues That Arise

  • A minor fault on one circuit shuts down lighting, kitchen appliances, and computers simultaneously.
  • Identifying the faulty appliance is more difficult.
  • In offices, power interruptions affect multiple departments simultaneously.

How To Fix It

  • Upgrade to individual RCBOs for each circuit.
  • Plan electrical layouts that balance loads across multiple RCDs.
  • Segment high-risk circuits (bathrooms, kitchens, EV chargers) with separate protection.

Ignoring Regular Testing

RCDs must be tested regularly to ensure they are still functional. Many homeowners and businesses overlook this routine check, assuming the device is fine unless it trips.

Why Testing Matters

  • The internal test button simulates a fault to ensure the trip mechanism works.
  • Internal faults may go unnoticed without regular testing until it’s too late.

Best Practices

  • Test every three months using the “T” button.
  • The RCD should immediately cut power. If it doesn’t, it’s faulty.
  • Document testing dates for future reference.

Compatibility Issues After Renovations Or Upgrades

When new appliances or circuits are added, like during a kitchen renovation or solar installation, existing RCDs may struggle to manage the changed electrical environment.

Common Problems

  • Increased leakage from modern devices.
  • Added circuits create load imbalances.
  • New devices introduce DC currents that old RCDs can’t detect.

How To Fix It

  1. Conduct a post-renovation safety inspection.
  2. Upgrade RCDs to appropriate types (Type A or RCBO).
  3. Reconfigure circuits to avoid overloading and shared neutrals.

Shared Neutral Connections

Older electrical setups sometimes use a single neutral wire for multiple circuits, known as shared neutrals. RCDs monitor both active and neutral currents, so shared neutrals confuse them.

Problems Caused

  • RCDs trip with no load or warning.
  • Power returns on a supposedly off circuit.
  • Poor performance from sensitive electronics.

How To Fix It

  • A qualified electrician should rewire the setup.
  • Each circuit needs a dedicated neutral to work correctly with RCDs.
  • Avoid makeshift fixes—compliance with AS/NZS 3000 is essential.

External Electrical Interference

In rare cases, RCDs may be affected by outside electrical issues that aren’t the result of a fault within the protected installation.

Common Sources

  • Power surges from the grid or local transformers.
  • Electromagnetic interference from nearby industrial equipment.
  • Faults in multi-tenant buildings where neutral paths are shared.

What You Can Do

  • Install surge protection devices.
  • Use high-quality RCDs with strong filtering capabilities.
  • Notify your power provider if grid faults are suspected.

Conclusion

RCDs are essential to electrical safety, but they are not fail-proof. Problems like nuisance tripping, outdated devices, environmental degradation, and poor installation are more common than many realise. Knowing what causes and how to address these issues can make a major difference in keeping your property and people safe.

Whether maintaining a home or managing a commercial building, proactive maintenance, proper installation, and timely upgrades to your RCDs can prevent serious accidents and ensure consistent protection.

Frequently Asked Questions

How Often Should I Test My RCDs At Home?

You should test your RCDs every three months using the built-in test button. Pressing this button simulates a fault, and the device should trip immediately. If it doesn’t, the RCD is likely faulty and should be checked or replaced by a licensed electrician.

Why Does My RCD Keep Tripping Even When Everything Seems Fine?

Faulty appliances, socket moisture, or multiple small leakages from various devices can cause frequent tripping. It may also indicate wiring issues or that your RCD is too sensitive or outdated. An electrician can identify the root cause and recommend a solution.

Can Old RCDs Handle New Appliances Like EV Chargers And Solar Inverters?

Many older RCDs, especially Type AC, cannot detect DC leakage currents produced by modern devices. This means they may not trip when needed, leaving your system unprotected. Upgrading to Type A or RCBOs is recommended for homes with newer appliances.